New lower prices on all Nano Detox Systems...

Nano Particle Equipment Instructions

Please read this manual entirely before using your NPEV device.

 Operating Instructions

1) Fill 5 gallon vessel with approximately 3 gallons of recommended NPEV solution (see below for formulas)

2) Connect wires, using supplied wire nuts or connectors (depending on model), from power supply to vessel coil wires.

3) Plug the power supply into 120VAC receptacle.

We recommend plugging into a GFCI (Ground Fault Circuit Interruption, such as in bathrooms) receptacle, however, any 120VAC source may be used.

4) Use for 20-30 minutes daily for one week then once or twice weekly as recommended or desired. 

Change solution as required, usually when particulate build up has saturated the solution to 25% or more.

PRECAUTIONS

DO NOT EXPOSE THE POWER SUPPLY TO WATER OR OTHER LIQUIDS.

Although all NPEV models have been designed and built to the highest standards, precautions must be taken when using all electrical appliances or equipment.

Cleaning and Maintenance

Unplug power supply from 120VAC receptacle.

Disconnect vessel from power supply via wire nuts or connectors, depending on model.

Clean vessel with mild or anti-bacterial detergent, warm or hot water and sponge or scrub brush.

Rinse thoroughly with hot then cold water. Rinse again with distilled or RO (reverse osmosis) water before adding NPEV solution.

OPTIONAL: add 90% Isopropyl alcohol to distilled or RO (reverse osmosis) water (1:10 ratio) after cleaning to completely eliminate any bacteria. Rinse again with distilled or RO (reverse osmosis) water before adding NPEV solution. 

Specifications

Capacity

5 US Gallons

Fill Level

Approx 3 US gallons

Power Supply input

120VAC

Power Supply output

19.5Vdc @ 3Amps

Coil Impedance

0.8 ohms

Wire Gauge/Type

14AWG – 19 strand copper

Max allowable coil current

30A

Fuse

5A (3AG fast blow)

LED Power Indicator

20mA

Voltmeter

0-100Vdc

Ammeter

0-10A

On-Off Switch

10A Maximum

Power Supply Disconnection Method

Wire Nuts

Polarity Sensitivity

None

 

Guaranteed minimum magnetic flux density

(3-axis measurement, all models)

2” inside vessel

xx milliGauss

2” outside vessel

xx milliGauss

12” outside vessel

xx milliGauss


How to test if your bucket power supply is working:



Formulas of Solution to use:

There are 3 solutions that the bucket can get filled with (from the Herbs Plus Beadworks website):
Use any of the three (3) formulas below.

Formula 1 - take 3 gallons of Vinegar (white) and add 1/8-1/4 cup of salt. Mix thoroughly and then connect the power supply. Sit with either one leg or both in the pail for 20-30 minutes.

Formula 2 – take 3 gallons of Distilled Water and 1-2 caps of DMSO, Citric acid 1/8-1/4 cup and Salt 1/8- 1/4 cup. Mix thoroughly and then connect the power supply. Sit with either one leg or both in the pail for 20-30 minutes.

Formula 3 - take TSP -1/8 cup Salt, 1/8 cup Citric Acid, Distilled water 3-3.5 gallons ( 12 litres for the metrically oriented). Mix thoroughly and then connect the power supply. Sit with either one leg or both in the pail for 20-30 minutes.
For more information, please contact:

HERBS PLUS AND BEADWORKS
1471 Ottawa Street
Windsor, ON
N8X 2G1
CANADA
Phone Number: 519-977-5351
Hours of Operation: Monday through Saturday 9am to 6pm Eastern time

Sale

Unavailable

Sold Out

Back to the top