Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground
Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING! - 2Ground

Digital 3-AXIS EMF RF Radiation ElectroSmog Power Isotropic Meter 38mv ~ 11v/m Range Made in Taiwan Tester FREE SHIPPING!

2Ground

Regular price $268.99 USD $268.99 USD Sale

Model Number: T95
Power: Electronic
DIY Supplies: Electrical
Usage: Other
Measuring range: 38mv ~ 11v/m
Frequency range: 50MHz ~ 3.5GHz
Manual data memory: 200 data sets (read storage)
Sampling Time: 2.5 times per second
Power Supply: 1 x 9V battery (included)
Battery life: approx. 15hrs
Weight: 178 g (battery not included)
Dimension: 195 mm x 60 mm x 60 mm

Product Description

RF Tri- Axis Meter is non directional (isotropic) measuring device with 3- channel measurement sensor(X,Y and Z) that is designed for a reliable measurement and monitoring of Radio- Frequency Electromagnetic Field strength. It has a frequency range of 50Mz ~ 3.5GHz.

 

RF Tri- Axis Meter indicates the level of electromagnetic pollution generated artificially which can be found wherever there is a voltage or current, electric (E) and magnetic (H) fields arises.

 

It was made in accordance with EMC Standards in force and its compatibility has been tested in accordance with EN 1326-1 (2006). In addition, this meter is Made in Taiwan, you can be sure of its high quality and accuracy.

 

Application:

  • High frequency (RF) electromagnetic wave field strength measurement
  • Mobile phone base station antenna radiation power density measurement
  • Wireless communication applications (CW, TDMA, GSM, DECT)
  • RF power measurement for transmitters
  • Wireless LAN (Wi-Fi) detection, installation
  • Wireless bug finder
  • Cellular /Cordless phone radiation safety level
  • Microwave oven leakage detection
  • Personal living environment EMF safety
  

bar-feature

 
  • 50MHz to 3.5GHz Frequency range
  • For isotropic measurements of electromagnetic fields
  • Non-directional (isotropic) measurement with three- channel measurement sensor
  • High dynamic range due to three- channel digital results processing w/ Instantaneous value (maximum and average value measured)
  • Configurable alarm threshold and memory function
  • Easy & safety to use
  • Low battery detector
  • Over load indication
  • Auto power off (adjustable from 0~99 min) with disable function
  • Made in Taiwan
 

bar-specs

 
  • MLCD Display: 4 1/2 digits with maximum reading 19999
  • Measuring range: 38mv ~ 11v/m
  • Frequency Range :  50MHz ~ 3.5GHz
  • Sensor type : Electrical field (E)
  • Specified measurement range :
    • CW signal (f>50MHz) : 38mV/m to 20.00V/m, 53.0uA/m to 53.74mA/m 0.1uW/m² 1.089W/m², 0.001uW/cm² ~ 108.9uW/cm²
    • Dynamic range : Typically 75dB
    • Absolute error at 1V/m and 50MHz
  • Frequency response:
    • Sensor taking into account the typical CAL factor:
      • ±2.4dB (50 MHz to 1.9GHz)
      • ±1.0dB (1.9GHz to 3.5GHz)
    • Isotropy deviation : Typically ±1.0dB (f 2.45GHz)
    • Overload limit : 0.42mW/cm² (11V/m) per axis
    • Overload limit : (0 to 50°C); ±0.2dB
  • Measurement units: mV/m , V/m , µA/m , mA/m , µW/m2,mW/m2 , µW/cm2
  • Display resolution: 0.1mV/m, 0.1µA/m, 0.001µW/m2, 0.001µW/cm2
  • Manual data memory: 200 data sets (read storage)
  • Sampling Time: 2.5 times per second
  • Alarm function: adjustable threshold with ON/ OFF
  • Memory Recall: records Maximum & AVG
  • Calibration factor CAL: adjustable
  • Operating Temperature : 0 ~50°C ( 32 ~122°F ) 
  • Ambient temperature : +23°C ±3°C
  • Relative air humidity : 25% ~ 75%
  • Power Supply: 1 x 9V battery (included)
  • Battery life: approx. 15hrs
  • Weight : 178 g (battery not included)
  • Dimension: 195 mm x 60 mm x 60 mm
 

 Comes with

1 x Tri-Axis RF Tester

1 x English User's manual

1 x 9V battery

1 x Carrying bag

 